Roof Ventilator

Share: FacebookTwitterStumble
We are leading supplier, trader, distributor & dealer of roof ventilator in chennai, tamilNadu & south India majorly. Our roofing ventilation has gained much acclaim due to our high quality range of Roofing Ventilation (Starvent). This superior technology sets us apart from the competition due to the low prices and technical stability.



Aluminum Ventilator

Enlarge View

Aluminum Ventilator

We are Leading Supplier, Trader, Distributor & Dealer of Aluminium Ventilator in Chennai, TamilNadu & South India Majorly. It is extremely popular in a number of industries because of its high quality. This ventilator is manufactured using high grade raw materials, we assure that our aluminium ventilator will not show signs of wear and tear or rust after long periods of time.


Fluorine Carbon Aluminum Ventilator

Enlarge View

Fluorine Carbon Aluminum Ventilator

We are Leading Supplier, Trader, Distributor & Dealer of Fluorine Carbon Aluminium Ventilator in Chennai, TamilNadu & South India Majorly. Leveraging on our superior manufacturing facility and intelligence of our team of experts, we provide a wide range of fluorine carbon aluminium ventilator. These are manufactured using top notch aluminium and are known for their long life and productivity.


Stainless Steel Ventilator

Stainless Steel Ventilator

We are Leading Supplier, Trader, Distributor & Dealer of Stainless Steel Ventilator in Chennai, TamilNadu & South India Majorly .Available at industry leading prices, our excellent range of stainless steel ventilators are known for its high quality stainless steel, and raw materials procured from reputable sources. It displays high resistance to corrosion and the forces of nature to make an excellent product.



Roof Ventilator FCP Coating

Enlarge View

Roof Ventilator FCP Coating

We are Leading Supplier, Trader, Distributor & Dealer of Roof Ventilator FCP Coating in Chennai, TamilNadu & South India Majorly. Roof Ventilator FCP Coating may locate the ventilator by inner hold of base flashing or accurate round mould.

1. The ideal installation position of a ventilator is a close to the ridge as possible. When locating, lay aside the base flashing on the roof and make the upward inclined edge of base flashing insert the gap below the metal flashing of the ridge 10cm or so.

2. Cutting the opening :

Taking the inner hole of base flashing as mould, draw up the outline of the opening, then cut the opening with cutting machine, repair and burnish the cutting edge. Cut the thermal cotton according to the shape with and staff thermal cotton and aluminum foil between the steel plate and thermal cotton.

3. Paste the waterproofing cement tape and apply waterproofing silicon glue :

Paste the waterproofing tape on the conjunction of the base flashing and the roof cover plate on the ridge. Paste the waterproofing glue tape on the top of wave crest with complete sides and apply the waterproofing silicon glue between foam and color steel plate then tear the paper skin of the glue tape.

4. Fix the base flashing :

 Fix the base flashing on the roof with at least 10 fixing screws or rivets (provided by users)

5. Install the vari pitch :

 Lay the vari pitch on the base flashing and revolve the movable part of vari pitch. Meanwhile adjust the whole position of the vari pitch and base flashing to make the top of the vari pitch horizontal.

Adjust the angle at 90° in the same direction by gradienter. After adjustment, draw the mark on the up-down movable parts of the vari pitch and between the vari pitch and base flashing with color pen.

6. Fixing the vari pitch :


 Fix the vari pitch onto the base flashing with at least 4 fixing screws.

Fix together two up-down movable parts of the vari pitch with 4 pieces of metal clip slice and 8 aluminum rivets. During operations, please make sure level the former mark.

7. Applying glue in inner parts :

 Apply the waterproofing silicon glue evenly with fingers on the up-down movable parts of the vari pitch conjunction parts between the vari pitch and the base flashing and around all screws. Mind! Taking the circle center as the criterion, at the position of 60° angle across the ridge, do not apply any glue in the conjunction place between the vari pitch and the base flashing. This aims at making condensate water of air dripping along the inner wall and exhaust out of the roof.

8. Fix the turbine heads of the vari pitch :

 Get for supporting arms of the turbine head stuck in the reserved holes of the vari pitch. Make sure the reserved holes of supporting arms accord with four reserved parts of the vari pitch (may use screwdriver to level) then fix the turbine head into vari pitch with four screws.

9. Check and adjust:

Check all screws or rivets whether firmed or not. Make sure the turbine head revolving smoothly, Sometimes turbine head is extruded to deform in transportation or installation process, you may make slight adjustment with hands. Lastly apply waterproofing silicon around the roam and base flashing.






Aluminum Ventilator

Fluorine Carbon Aluminum Ventilator

Stainless Steel Ventilator

Roof Ventilator FCP Coating

Sri Ramana EnterprisesShowroom

View all our products / services as a slide show.

Play Now

Contact Us

Sri Ramana Enterprises
Mr. Gunasekarar R. (Proprietor)
No. 71, 1st Floor Valluvar Salai, Near Ramapuram BSNL Office, Ramapuram
Chennai - 600 089, Tamil Nadu, India

Contact via E-mail

Contact via SMS



Member IndiaMART.com © Sri Ramana Enterprises. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

Business Enquiry Form


(* represents compulsory fields )

*Describe Your Requirements in Detail
Please Fill Your Contact Information
*Contact Person:
*Email:
Company:
Street Address:
*Country:
*Telephone:
Mobile:
Website:
*Enter the code: